REPRESENTATIVE CONCEPTLaboratory Vacuum Planetary Mixer
Li-ion Laboratory EquipmentLaboratory slurry mixing under controlled pressure.

Intended for controlled drying of compatible electrode samples or components before assembly, where temperature exposure, residual moisture and solvent handling require a defined procedure.
| Parameter | Indicative Configuration |
|---|---|
| Machine type | Laboratory Vacuum Drying Oven |
| Capacity range | 25–150 L |
| Standard models | 25 / 50 / 100 / 150 L |
| Temperature range | Ambient +10 to 200°C |
| High-temperature configuration | Up to 250°C, optional |
| Temperature control | Digital PID |
| Temperature control stability | Target ±1°C at control sensor |
| Chamber temperature uniformity | Subject to loaded mapping and validation |
| Vacuum level | Target ≤10 mbar absolute, system-dependent |
| Vacuum monitoring | Digital absolute-pressure sensor; analog optional |
| Vacuum pump | External rotary-vane or suitable dry pump |
| Vacuum connection | KF25 or appropriately sized fitting |
| Chamber material | SS304; SS316L optional |
| Chamber design | Welded stainless-steel vessel engineered for external pressure |
| External construction | Fabricated, powder-coated steel |
| Heating system | Multi-sided external heating |
| Heating power | Preliminary 0.8–4.5 kW, model-dependent |
| Thermal insulation | High-temperature insulation |
| Shelves | Removable stainless-steel trays |
| Door seal | Temperature- and process-compatible vacuum gasket |
| Viewing window | Optional, engineered for vacuum service |
| Vacuum release | Controlled vent; inert-gas purge optional |
| Timer | Programmable, target 0–999 minutes |
| Temperature sensor | PT100 or suitable thermocouple |
| Control system | Digital controller; PLC/HMI optional |
| Electrical supply | 230 V / 415 V AC, model-dependent |
| Safety | Overtemperature protection, engineered vacuum enclosure, electrical safeguards |
| Application | Battery electrode sheets, materials and laboratory component drying |
Specifications represent preliminary configurable design targets. Final parameters, material compatibility, performance and availability will be confirmed after application review and engineering validation.
The temperature-stability target applies at the control sensor and does not establish chamber uniformity. Loaded temperature mapping is required. The vacuum target is absolute pressure; performance under vapour or solvent load depends on the selected chamber and vacuum system.
Configurable laboratory vacuum drying machinery is intended for battery R&D and laboratory process applications. The proposed configuration combines a stainless-steel chamber, controlled multi-sided heating, removable shelves and a configurable external vacuum system. Controlled venting and optional inert-gas backfill support application-specific process planning. Heat transfer, sample loading and vapour load affect drying behaviour; operating targets require validation for the selected process.
Battery electrode-sheet and material drying, compatible laboratory component conditioning, and research preparation before controlled-atmosphere transfer. Confirm the intended process, materials and acceptance method during application review.
Mechanical interfaces, operating mode and control requirements are defined during engineering review. Available configuration choices depend on the agreed equipment scope.
The proposed standard configuration uses commercially available PID controllers, temperature sensors, heaters and vacuum components with fabricated or machined mechanical assemblies. PLC/HMI remains optional. Configuration and final quotations depend on the enquiry and engineering assessment; this listing does not establish manufacture, completed testing, stock or immediate dispatch.
Electrical supply, external vacuum pump, connections, exhaust and vapour-management arrangements must be selected for the model and process. Optional inert-gas backfill requires appropriate gas-supply and venting provisions. Pump protection, condensate handling and solvent compatibility require application-specific assessment.
Vacuum-vessel integrity under external pressure, thermal design, window and gasket suitability, vapour handling and applicable safety requirements require engineering verification before final quotations. Temperature uniformity requires loaded mapping. The vacuum target is not guaranteed under solvent load. No solvent compatibility, explosion protection or certification is established by these proposed configurations.
A documented risk assessment, guarding review, material compatibility check and application-specific operating procedure are required before use. No CE, UL, IEC, hazardous-area approval or other certification is established by this listing. Conformity documentation depends on the agreed scope and destination requirements.
Read the Product Information Disclaimer
Request technical documentation and an application-specific configuration with your enquiry.
This listing represents an intended equipment or engineering offering. Feasibility, configuration and availability require confirmation. Please request the current engineering and supply status.
Share your materials, required capacity, process constraints and acceptance criteria. The team will review feasibility before confirming any custom scope.
REPRESENTATIVE CONCEPTLaboratory slurry mixing under controlled pressure.
REPRESENTATIVE CONCEPTLaboratory rotor-stator dispersion.
REPRESENTATIVE CONCEPTLaboratory blade coating of electrode coupons.