REPRESENTATIVE CONCEPTLaboratory High-Shear Mixer / Homogenizer
Li-ion Laboratory EquipmentLaboratory rotor-stator dispersion.

Configurable laboratory vacuum double planetary mixer intended for Li-ion battery electrode slurry preparation and material research. The proposed range supports laboratory formulation planning with nominal working capacities from 0.5 to 5 L. These are preliminary development targets, not validated machine ratings.
| Parameter | Indicative Configuration |
|---|---|
| Equipment type | Laboratory Vacuum Double Planetary Mixer |
| Working capacity | 0.5–5 L |
| Standard capacity variants | 0.5 / 1 / 2 / 5 L |
| Vessel design volume | Approximately 1.5–2× nominal working volume |
| Mixing mechanism | Dual planetary agitators with wall scraper |
| Planetary revolution speed | Target 0–60 RPM, adjustable |
| Agitator rotation speed | Target 0–150 RPM, adjustable |
| High-speed disperser | Optional, target 0–3,000 RPM |
| Mixing drive power | Indicative 0.4–1.5 kW, model-dependent |
| Disperser drive power | Indicative 0.75–1.5 kW, model-dependent |
| Operating vacuum | Target −0.08 to −0.095 MPa gauge |
| Vessel material | SS304 standard; SS316L optional |
| Vessel arrangement | Removable, sealed stainless-steel vessel |
| Speed control | Variable-speed electronic drive |
| Mixing timer | Programmable, target 0–999 minutes |
| Temperature monitoring | Digital temperature measurement |
| Heating/cooling | Optional jacketed vessel |
| Vessel lifting | Manual or motorised, depending on model |
| Vacuum pump | Integrated or external, configuration-dependent |
| Control system | Digital controller; PLC/HMI optional |
| Electrical supply | 230 V AC single-phase / 415 V AC three-phase, configuration-dependent |
| Safety provisions | Emergency stop, access/lift interlocks and electrical protection |
| Application | Li-ion anode/cathode slurry preparation and laboratory R&D |
Specifications represent preliminary configurable design targets. Final parameters, material compatibility, performance and availability will be confirmed after application review and engineering validation.
The proposed mixing arrangement uses dual planetary agitators with a wall scraper for controlled incorporation of powders, binders and solvents. Vacuum-assisted operation is intended to reduce entrained air; mixing behaviour and process results require validation with the actual formulation.
Laboratory preparation of anode and cathode slurries, controlled powder/binder/solvent mixing, small-batch formulation development, and development of repeatable laboratory process-trial protocols. Confirm the intended process, materials and acceptance method during application review.
Mechanical interfaces, operating mode and control requirements are defined during engineering review. Available configuration choices depend on the agreed equipment scope.
Discuss manual or automated operation, local HMI, recipe control, PLC interfaces and process data requirements where appropriate. These options require scope confirmation.
Electrical supply, compressed air, cooling, exhaust, vacuum, floor loading and controlled-atmosphere requirements must be assessed against the selected configuration.
Use with NMP, flammable solvents or hazardous atmospheres requires documented process and electrical risk assessment. No solvent suitability, explosion-proof construction, ATEX, IECEx or other certification is established. Drive sizing, speed limits, vessel/vacuum integrity and the proposed safety interlocks require engineering validation.
A documented risk assessment, guarding review, material compatibility check and application-specific operating procedure are required before use. No CE, UL, IEC, hazardous-area approval or other certification is established by this listing. Conformity documentation depends on the agreed scope and destination requirements.
Read the Product Information Disclaimer
Request technical documentation and an application-specific configuration with your enquiry.
This equipment is under development. Design details, tested performance and delivery commitments require confirmation. Please request the current engineering and supply status.
Share your materials, required capacity, process constraints and acceptance criteria. The team will review feasibility before confirming any custom scope.
REPRESENTATIVE CONCEPTLaboratory rotor-stator dispersion.
REPRESENTATIVE CONCEPTLaboratory blade coating of electrode coupons.
REPRESENTATIVE CONCEPTBenchtop slot-die coating trials.