LI-ION BATTERY EQUIPMENT & AUTOMATIONVADODARA, INDIA · INTERNATIONAL ENQUIRIES
AI-generated representative concept. Not a photograph of a completed Amplemech Battery Equipment & Automation machine. Research test-cell hardware equipment family.
AI-generated representative concept. Not a photograph of a completed Amplemech Battery Equipment & Automation machine.
Li-ion Laboratory EquipmentAMB-STC-01Partner-Supplied

Split Test Cell / Three-Electrode Cell

Intended for re-openable electrochemical research assemblies, including a reference-electrode arrangement where the experimental design requires one.

Intended partner-supply route only. No named partner appointment, authorisation, available machine, scope or delivery is confirmed by this listing.

Technical Specifications

Split Test Cell / Three-Electrode Cell — indicative configuration
Technical ParameterIndicative Configuration
Equipment typeReusable Split Battery Test Cell
Standard electrode diametersØ10 / 15 / 20 mm
Optional insert diameterØ5–24 mm, selected design
Cell configurationTwo-electrode
Three-electrode arrangementOptional dedicated variant
AssemblyThreaded mechanical closure
Main contact materialSS304 / SS316L, selected design
Contact surface coatingOptional gold plating
Electrical insulationPTFE / suitable polymer
Cell sealReplaceable chemically compatible O-rings
Maximum specimen-stack heightPreliminary up to 6 mm
Contact pressureMechanical spring / threaded compression
Pressure adjustmentSpacer/spring or controlled torque arrangement
Compression springStainless steel
Electrode positioningInterchangeable precision insert
Separator positioningDedicated guide / spacer
Electrical terminalsPositive/negative connection points
Test compatibilityCharge-discharge / EIS, with suitable instruments
Wetted materialsSelected for electrolyte compatibility
CleaningDisassemblable reusable components
Glove-box useCompact manual operation
Temperature capabilityMaterial and seal-dependent; not universally rated
Optional temperature classApplication-specific; complete assembly temperature rating requires verification
Leak-tightnessSubject to sealing design and tests
Machined componentsPrecision turned/milled construction
Surface finishApplication-dependent
ApplicationReusable electrochemical battery-material testing

Specifications indicate preliminary equipment configurations. Final technical parameters, performance, material compatibility and supply arrangements will be confirmed following application review and detailed engineering.

Proposed model configurations

ModelConfiguration
AMB-STC-10Ø10 mm
AMB-STC-15Ø15 mm
AMB-STC-20Ø20 mm
AMB-STC-CCustom electrode insert

This product is a reusable electrochemical test fixture, not a production machine. Two-electrode operation is the proposed base configuration; three-electrode testing requires a dedicated optional arrangement. Electrode sizes and stack height are proposed configuration targets. Temperature limits require verification of the complete assembly, seals, insulation, contacts and operating pressure; no universal temperature or leak-tightness rating is established.

Intended operating principle

Reusable split test cells support battery-material research with configurable electrode sizes, precision electrical contacts and replaceable sealing components. Threaded closure, selected insulating components and a spring or controlled compression arrangement hold the specimen stack. A dedicated optional three-electrode arrangement can be evaluated with suitable test instrumentation.

Principal applications

Electrode screening, three-electrode investigations and repeatable assembly studies using compatible materials. Confirm the intended process, materials and acceptance method during application review.

Configuration & integration

Mechanical interfaces, operating mode and control requirements are defined during engineering review. Available configuration choices depend on the agreed equipment scope.

  • AMB-STC-10 — Ø10 mm
  • AMB-STC-15 — Ø15 mm
  • AMB-STC-20 — Ø20 mm
  • AMB-STC-C — Custom electrode insert

Manual threaded assembly and interchangeable inserts provide the proposed standard arrangement. Gold-plated contacts and a dedicated three-electrode variant are optional; external charge-discharge or EIS instruments are selected separately.

Utilities & installation

Configuration, component selection and supply feasibility follow the customer application review. Mechanical assemblies, specialist subsystems and integration are confirmed for the agreed scope. Utilities and facility interfaces depend on the selected configuration. This enquiry-led listing does not establish stock, completed manufacture or testing, immediate dispatch, or a confirmed supplier partnership.

Engineering & safety considerations

Electrolyte compatibility, O-ring sealing, insulation, contact materials, compression and operating pressure require assessment. Temperature capability must be verified for the complete assembly; no general high-temperature suitability or leak-proof guarantee is established. Electrical connections, sample handling and cleaning procedures require application review.

A documented risk assessment, guarding review, material compatibility check and application-specific operating procedure are required before use. No CE, UL, IEC, hazardous-area approval or other certification is established by this listing. Conformity documentation depends on the agreed scope and destination requirements.

Read the Product Information Disclaimer

Typical engineering workflow

  1. Define the input materials, geometry and process objective.
  2. Agree the configuration, interfaces and safety requirements.
  3. Establish a trial plan and measurable acceptance criteria.
  4. Confirm technical scope before a quotation or delivery commitment.

Technical documentation

Request technical documentation and an application-specific configuration with your enquiry.

Questions about this equipment

Is this equipment available for immediate delivery?

Intended partner-supply route only. No named partner appointment, authorisation, available machine, scope or delivery is confirmed by this listing. Please request the current engineering and supply status.

Can the configuration be adapted to our application?

Share your materials, required capacity, process constraints and acceptance criteria. The team will review feasibility before confirming any custom scope.

Continue exploring

Related equipment