REPRESENTATIVE CONCEPTLaboratory Vacuum Planetary Mixer
Li-ion Laboratory EquipmentLaboratory slurry mixing under controlled pressure.

Intended to cut circular electrode specimens from coated foil for coin-cell assembly, with edge quality and particulate generation treated as key process checks.
| Parameter | Indicative Configuration |
|---|---|
| Machine type | Precision Coin Cell Electrode Disc Cutter |
| Models | AMB-LDC-M / P / C |
| Actuation | Manual lever; pneumatic optional |
| Standard cutting diameters | Ø12 / 14 / 15 / 16 / 18 / 19 / 20 mm |
| Custom cutting sizes | Ø6–24 mm |
| Compatible materials | Copper foil, aluminium foil, coated electrodes and selected separator films |
| Material thickness | Target 0.005–0.3 mm; up to 0.5 mm subject to application trials |
| Punch stroke | Target 20–25 mm |
| Punch/die material | Hardened alloy tool steel |
| Tool hardness | Target 58–62 HRC |
| Punch/die clearance | Selected to suit material and thickness |
| Punch guidance | Precision guide bushes and aligned die holders |
| Die changeover | Interchangeable matched tooling |
| Manual mechanism | Mechanical lever with guided ram |
| Pneumatic supply | Proposed 5–6 bar, pneumatic version |
| Return mechanism | Spring or pneumatic return |
| Sample collection | Removable collection tray with appropriate ejection arrangement |
| Main structure | Machined steel/aluminium construction |
| Surface protection | Corrosion-resistant finish |
| Mounting | Benchtop |
| Glove-box use | Optional compact version, subject to dimensional compatibility |
| Electrical supply | Not required for manual version |
| Safety | Cutting-zone guarding; suitable interlocked/two-hand control for powered version |
| Applications | Circular anode, cathode and separator sample preparation |
Specifications represent preliminary configurable design targets. Final parameters, material compatibility, performance and availability will be confirmed after application review and engineering validation.
The manual model is the standard configuration. Pneumatic actuation is a separate optional configuration requiring guarding, control-circuit safety review and validation. Cutting diameter and thickness combinations, edge quality, dimensional accuracy, tool life and cutting force require material-specific engineering validation.
This compact laboratory disc cutter is intended to prepare circular electrode and selected separator samples for battery cell research. The standard manual configuration uses a mechanical lever, guided punch assembly and replaceable hardened punch-and-die sets, without electrical power. Interchangeable precision dies and guided alignment support the proposed configurable cutting diameters; actual edge quality and dimensions require trials with the selected material.
Circular anode, cathode and separator sample preparation for coin-cell research, comparative material testing and laboratory sample production. Confirm the intended process, materials and acceptance method during application review.
Mechanical interfaces, operating mode and control requirements are defined during engineering review. Available configuration choices depend on the agreed equipment scope.
The standard manual version uses mechanical lever actuation and a guided ram, without motorised controls. The optional pneumatic configuration requires a separately validated guarded operating sequence and suitable interlocked or two-hand controls.
The standard manual version requires no electrical supply. The optional pneumatic version has a proposed air supply of 5–6 bar; its pneumatic circuit, isolation, guarding and control-safety requirements must be assessed for the selected configuration.
Punch/die clearance, tool hardness, guidance and the proposed material-thickness envelope require engineering validation using representative foils, coatings and separator films. No burr-free cutting, dimensional accuracy, tool life or cutting-force rating is guaranteed. Powered actuation requires cutting-zone guarding and control-circuit safety validation. Glove-box fit and ejection arrangements require configuration checks; no proprietary tooling or patented mechanism is represented as an Amplemech design.
A documented risk assessment, guarding review, material compatibility check and application-specific operating procedure are required before use. No CE, UL, IEC, hazardous-area approval or other certification is established by this listing. Conformity documentation depends on the agreed scope and destination requirements.
Read the Product Information Disclaimer
Request technical documentation and an application-specific configuration with your enquiry.
This equipment is under development. Design details, tested performance and delivery commitments require confirmation. Please request the current engineering and supply status.
Share your materials, required capacity, process constraints and acceptance criteria. The team will review feasibility before confirming any custom scope.
REPRESENTATIVE CONCEPTLaboratory slurry mixing under controlled pressure.
REPRESENTATIVE CONCEPTLaboratory rotor-stator dispersion.
REPRESENTATIVE CONCEPTLaboratory blade coating of electrode coupons.